All citations for The Chateau At Brooklyn Rehabilitation and Nursing

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to The Chateau At Brooklyn Rehabilitation and Nursing

Last standard health inspection on record

June 21, 2024

This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.

Showing 1 to 13 of 13 citations

  1. No harm, with potential for more than minimal harm

    Develop and maintain an Emergency Preparedness Program (EP).

    Pattern (more than a few residents). CMS level E.

    Emergency preparedness citation E-0004, Emergency Preparedness Deficiencies. Inspection of June 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 14, 2024).

  2. No harm, with potential for more than minimal harm

    Meet requirements for the installation and maintenance of electrical systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0911, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of June 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 14, 2024).

  3. No harm, with potential for more than minimal harm

    Have power receptacles that are properly grounded.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0912, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of June 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 14, 2024).

  4. No harm, with potential for more than minimal harm

    Ensure equipment listed for use in oxygen-enriched atmospheres are correctly labeled.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0928, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of June 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 14, 2024).

  5. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of May 25, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 18, 2022).

  6. No harm, with potential for more than minimal harm

    Have an enclosure around a vertical opening shaft.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0311, Smoke Deficiencies. Inspection of May 25, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 18, 2022).

  7. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 25, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 18, 2022).

  8. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of June 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 16, 2019).

  9. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of June 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 14, 2024).

  10. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of June 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 14, 2024).

  11. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of May 25, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 18, 2022).

  12. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of June 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 16, 2019).

  13. No harm, with potential for minimal harm

    Provide at least two remote exits on each floor or fire section of the building.

    Pattern (more than a few residents). CMS level B.

    Fire safety citation K-0252, Egress Deficiencies. Inspection of June 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 16, 2019).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.