All citations for The Commons at Lisle Creek Estates

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to The Commons at Lisle Creek Estates

Last standard health inspection on record

December 19, 2025

Showing 1 to 25 of 34 citations

  1. Harm to a resident

    Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

    Isolated (one or a few residents). CMS level G.

    Health citation F-0689, Quality of Life and Care Deficiencies. Inspection of September 14, 2023. Found during a complaint inspection.

    The home gave a date the problem would be corrected (September 25, 2023).

  2. No harm, with potential for more than minimal harm

    Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

    Widespread (many residents). CMS level F.

    Health citation F-0812, Nutrition and Dietary Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 19, 2026).

  3. No harm, with potential for more than minimal harm

    Make sure that the nursing home area is safe, easy to use, clean and comfortable for residents, staff and the public.

    Widespread (many residents). CMS level F.

    Health citation F-0921, Environmental Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 19, 2026).

  4. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 28, 2026).

  5. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0511, Services Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  6. No harm, with potential for more than minimal harm

    Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

    Widespread (many residents). CMS level F.

    Health citation F-0812, Nutrition and Dietary Deficiencies. Inspection of September 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 4, 2024).

  7. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  8. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 28, 2026).

  9. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  10. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  11. No harm, with potential for more than minimal harm

    Provide care and assistance to perform activities of daily living for any resident who is unable.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0677, Quality of Life and Care Deficiencies. Inspection of September 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 1, 2024).

  12. No harm, with potential for more than minimal harm

    Provide and implement an infection prevention and control program.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0880, Infection Control Deficiencies. Inspection of September 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 1, 2024).

  13. No harm, with potential for more than minimal harm

    Implement a program that monitors antibiotic use.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0881, Infection Control Deficiencies. Inspection of September 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 1, 2024).

  14. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of September 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 10, 2024).

  15. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of September 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 10, 2024).

  16. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of September 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 10, 2024).

  17. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of September 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 10, 2024).

  18. No harm, with potential for more than minimal harm

    Provide care and assistance to perform activities of daily living for any resident who is unable.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0677, Quality of Life and Care Deficiencies. Inspection of October 5, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 31, 2023).

  19. No harm, with potential for more than minimal harm

    Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0758, Pharmacy Service Deficiencies. Inspection of October 5, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 31, 2023).

  20. No harm, with potential for more than minimal harm

    Ensure menus must meet the nutritional needs of residents, be prepared in advance, be followed, be updated, be reviewed by dietician, and meet the needs of the resident.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0803, Nutrition and Dietary Deficiencies. Inspection of October 5, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 31, 2023).

  21. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of October 5, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 3, 2023).

  22. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of October 5, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 3, 2023).

  23. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of October 5, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 3, 2023).

  24. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0511, Services Deficiencies. Inspection of October 5, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 3, 2023).

  25. No harm, with potential for more than minimal harm

    Provide appropriate treatment and care according to orders, resident’s preferences and goals.

    Isolated (one or a few residents). CMS level D.

    Health citation F-0684, Quality of Life and Care Deficiencies. Inspection of December 19, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 19, 2026).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.