All citations for The Riverside

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to The Riverside

Last standard health inspection on record

November 20, 2024

Showing 1 to 16 of 16 citations

  1. No harm, with potential for more than minimal harm

    Have proper power supply for life support equipment.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0915, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  2. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of November 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2024).

  3. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  4. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  5. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  6. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  7. No harm, with potential for more than minimal harm

    Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0362, Smoke Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  8. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  9. No harm, with potential for more than minimal harm

    Use approved construction type or materials.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0161, Construction Deficiencies. Inspection of November 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2024).

  10. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of November 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2024).

  11. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of November 20, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2024).

  12. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  13. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

  14. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of November 9, 2020. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 18, 2020).

  15. No harm, with potential for more than minimal harm

    Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0362, Smoke Deficiencies. Inspection of November 9, 2020. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 18, 2020).

  16. No harm, with potential for minimal harm

    Address subsistence needs for staff and patients.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0015, Emergency Preparedness Deficiencies. Inspection of February 22, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 31, 2023).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.