All citations for Wecare at The Green Home

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Wecare at The Green Home

Last standard health inspection on record

December 13, 2024

Showing 1 to 16 of 16 citations

  1. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of December 13, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 4, 2025).

  2. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of December 13, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 4, 2025).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of December 13, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 4, 2025).

  4. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of December 13, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 4, 2025).

  5. No harm, with potential for more than minimal harm

    Use approved construction type or materials.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0161, Construction Deficiencies. Inspection of January 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 1, 2024).

  6. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of January 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 1, 2024).

  7. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 1, 2024).

  8. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of January 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 1, 2024).

  9. No harm, with potential for more than minimal harm

    Meet requirements for the installation and maintenance of medical gas and medical vacuum systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0902, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 1, 2024).

  10. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 1, 2024).

  11. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of January 20, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 28, 2023).

  12. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 20, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 28, 2023).

  13. No harm, with potential for more than minimal harm

    Ensure gas and vacuum piping is labeled.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0909, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 20, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 28, 2023).

  14. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 20, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 28, 2023).

  15. No harm, with potential for minimal harm

    Establish policies and procedures for volunteers.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0024, Emergency Preparedness Deficiencies. Inspection of January 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 1, 2024).

  16. No harm, with potential for minimal harm

    Conduct testing and exercise requirements.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0039, Emergency Preparedness Deficiencies. Inspection of January 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 1, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.